Fluorescent Microscope
Model:
FLM-67
¡¡
The
Infinity Corrected Optical System design has corrected chromatic
aberration on the base traditional optical system, A significant
development in optical performance and versatility. It is suited
for fluorescent microscopy. It is also used in Biology,
latrology, immunology, genetics, material science, etc.
¡¡ |
-
Optical
System: The Infinity Corrected Optical System design has
corrected chromatic aberration on the base
-
Eyepiece: PL10X high eye-point plan eyepiece, 22mmm view
of field can provide wide and clearly watching space.
-
Objectives: infinity plan achromatic objective 4X, 10X,
20X, 40X, 100X
-
Viewing
head: Gemel type of binocular head with an inclination of
30¡ã
-
Reversed quintuple nosepiece
-
focus
adjustment: Coaxial focus system with torque and coarse
adjustment
-
Stage:
Double layers mechanical stage, size: 175x145mm, move
range 75x50mm
-
Illumination: with transmitted illumination & fluorescence
reflected illumination
|
Technical Data for
RFL Fluorescence Microscope
-
Optical system: The Infinity Corrected
Optical System design has corrected chromatic aberration on the base
-
Head: Gemel type of binocular head, 45¡ã
inclined,
Gemel type of trinocular
head, 45¡ã inclined,
light splitting rate:
binocular 100%, binocular 20%/ trinocular 80%,
-
Eyepiece: PL10X high-eye point plan
eyepiece, line field 22mm
PL15X high-eye point plan eyepiece, line field 16mm
-
Nosepiece: Reversed quintuple nosepiece
-
Objective: Infinite plan achromatic
objective: ( 4X, 10X, 20X, 40X, 100X )
-
Focus system: Coaxial focus system with
torque adjustment,
Work distance of every circle: coarse focus: 25mm, precision 0.002mm
-
Stage: Double layers mechanical stage, size:
175x145mm, Low coaxial focus adjustor for left or right hand
-
transmitted illumination system: Adopt
90-240V wide voltage, inside it is transmitted Kohler illumination, the
6V/30W Halogen bulb; center presetting, adjustable brightness,
-
N.A.1.2/0.22 swing out achromatic condenser
-
reflected fluorescent illumination: it can
assemble 4 groups of fluorescent filters at the same time, it has center
adjustable iris diaphragm, ¦µ32mm filter, push-pull sunvisor
-
Mercury lamp box: 100W Mercury Lamp,
adjustable center, with adjustable reflecting mirror
Mercury lamp power supply box: with 90-245 VAC
¡¡
Specification
¡¡
¡¡ |
Outfit |
Parts |
Specification |
FLM-67 |
Eyepiece (pair) |
PL10X/22mm plan eyepiece(¦Õ30)£¬eye-cap
|
yes |
PL10X plan cross eyepiece(¦Õ30) with cross |
¡¡ |
PL15X/16mm plan eyepiece(¦Õ30) |
¡¡ |
Plan achromatic objective |
Infinity Plan achromatic objective 4X |
¡¡ |
Infinity Plan achromatic objective 10X |
yes |
Infinity Plan achromatic objective 20X |
yes |
Infinity Plan achromatic objective 40X |
yes |
Infinity Plan achromatic objective 100X |
yes |
Head |
30¡ãBinocular head(Infinity) |
¡¡ |
30¡ãTrinocular head(Infinity) |
yes |
Nosepiece |
Reversed quintuple nosepiece |
yes |
Stand |
Built in low position coaxial coarse&fine focusing system |
yes |
Stage |
175 x 145mm mechanical stage, adjusting for right |
yes |
175 x 145mm mechanical stage, adjusting for left |
¡¡ |
transmitted illumination system |
90V-240V wide voltage, |
yes |
6V/30W Halogen bulb; center presetting, adjustable brightness, |
N.A.1.2/0.22 swing out achromatic condenser |
Filter |
Yellow filter(¦Õ45) |
¡¡ |
Green filter(¦Õ45) |
¡¡ |
Blue filter(¦Õ45) |
¡¡ |
Neutral filter(¦Õ45) |
¡¡ |
Photography device |
Photo tube(with PK) |
¡¡ |
3.2X photography eyepiece |
¡¡ |
Fluorescence attachment |
reflected fluorescent illumination |
yes |
100W Mercury Lamp |
yes |
Mercury lamp power supply box |
yes |
OSRAM 100W DC Mercury Lamp |
yes |
fluorescent filter groups: |
UV |
¡¡ |
V |
¡¡ |
B |
yes |
G |
yes |
sunvisor |
¡¡ |
yes |
|
¡¡ |
|
|
|
|
|